Villa Elevator

Warm Space

It is exclusively designed for personal space, to create harmonious and comfortable lives. As one of the important components of the family, the villa elevator creates the quality experience where the floor space are interacted, and makes the whole vila space designed appropriately. The vila elevator meets the perfect need of connecting the up and down space closely, making family space warm, harmonious, comfortable and convenient.

Introduction

Green, energy-saving, environmental protection

Based on the use of the villa, it will enter into dormant state while stopping for long time, and minimize the consumption of the energy.

Secure, reliable and re-assuring

It is configured with the spare power supply, and the real-time monitoring, fault self-help system and emergent call system can guarantee the security of the passengers.

Customized car decoration

There are many decoration styles that meet the customized needs, and it is beautiful and generous, without losing its style.

Parameter Table

Villa Elevator Construction (Side set)

Rated Load(kg)Rated Speed(m/s)Net dimension of car(mm)Mode of door openDimension of door opening(mm)Dimension of hoistway(mm)minimum top(mm)minimum pit(mm)Host power(Kw)Maximum lifting height(m)minimum layer spacing(mm)
LDVCWxCDхCHOPxOPHHWхHDMin OHMin PITPMax THMin D
320

 

0.41150×1000х2100center opening700×20001750×125031004501.1122400
320

 

0.41150×1000х2100side opening900х20001750×1300
4000.41150×1100х2100center opening700×20001750×1350
4000.41150×1100х2100side opening900х20001750×1400

Details PC version

Well layout

Villa Elevator Construction (Backset)

Rated Load(kg)Rated Speed(m/s)Net dimension of car(mm)Mode of door openDimension of door opening(mm)Dimension of hoistway(mm)minimum top(mm)minimum pit(mm)Host power(Kw)Maximum lifting height(m)minimum layer spacing(mm)
LDVCWxCDхCHOPxOPHHWхHDMin OHMin PITPMax THMin D
320

 

0.41150×1000х2100center opening700×2000

 

1550х145031004501.1122400
320

 

0.41150×1000х2100side opening800х20001500×1500
4000.41150×1100х2100center opening700×20001550х1450
4000.41150×1100х2100side opening800х20001500×1600

Details PC version

Well layout

Standard Function

FunctionDescription of functions
>Automatic operationThe lift automatically runs and stops, opens / shuts the door according to designated command.
>Operation by operatorThe lift automatically runs and stops, manually shuts the door according to designated command.
>Overhaul operationUnder repair and inspection conditions, the lift runs at inspection speed through operating
“slow up / slow down” buttons.
>Automatic door-shut
time-delay
After the car door has been opened completely, it keeps the door open condition. It automatically
shuts the dnnr after time-delav.
>Call for opening of this floorWhen the lift is shutting the door or it does not start but has closed the door, when there is any
outer calling from this landing, it will reopen the door.
>Light curtain protectionWhen optical curtain has been shaded,it immediately
stops door-shut action and automatically opens the door.
>Overload none door-shutIt does not shut the door in overload. And it is bright from overload lamp. The buzzer rings.
It shows CZ or overload In the car and does not start the Ilft
>Full-load direct runningWhen it reaches the rated load, it only responds to internal selection instead of outer calling.
>Automatic lighting controlIn the stipulated time, If the lift does not receive any travel command, the lighting will a utomatically
die out. It automatically opens at command.
>Firefight returnWhen It starts home landing fire-fighting switch, all the commands will be cancelled then.
The lift Immediately drives to the designated landing and park there.
>Mal-operation removalRepeatedly operate internal selective button to cancel mal-operation registration
>Main contactor protectionAfter the lift executes door-shut command, if the door has not been closed within the
stipulated time, it will re-open the door and then shut it again.
>Service floor settingThe lift only serves the set floor.
>Home landing floor settingUnder the automatic condition, if there is automatic ally run to the set landing. no command within certain period, the car will
>Landing floor, direction display in the carIt shows the landing floor of the lift, the direction where the lift is going to travel in the car,
>Direction chosen by driverThe running direction Is determined by the driver’s directive.
>Trouble diagnosisWhen there Is something wrong in the travel process, it will automatically diagnose the trouble
cause, display in the operation panel and automatically store the latest trouble Information.
>Safety circuit protectionIf safety circuit is disconnected, the lift will immediately stop the travel.
>Door Interlocking
protection
If It closes all of door Interlocking, it can then start the Ilft. If door Interlocking is disconn ected or
trembled, the lift will stop the operation.
>Travel contactor
protection
The system can detect whether motor circuit contactor action is reliable or not. If any abnorma
condition happens, it will stop the lift travel.

 

FunctionDescription of functions
>Brake test protectionIt Implement real-time monitor to the brake open / shut through brake arm test switch. If the brake
has been opened improperly, the system will not allow the lift to start.
>Terminal speed change and landing floor number correctionAfter the system detect terminal switch in travel, the lift will be forced to change the speed and
automatically correct the landing floor display.
>Position-Limit protectionIf the system detects limit switch action, It will immediately stop the lift travel.
>Limit protectiorIf the system detects limit switch action, the whole system will Immediately lose power
>Over-speed protectionWhen the lift up / down exceeds 1.2 times of the rated speed, it will cut off control mains and stop the lift travel.
>Landing floor, direction displayThe floor landing shows the landing floor that the lift travels and where it travels also.

Optional Function

FunctionDescription of functions
>Opposite door service settingCorrectly open / shut the door in the corresponding floor according to service setting.
>Fire-fighting runningAfter fire switch is closed, the system enters into fire-fighting running.
>Parallel connection controlTwo-lift parallel connection control automatically responds the command according to rapid energy-saving
principle so as to Increase the lift travel efficiency.
>Group supervisionThe system can simultaneously control the travel of eight-lift. The function is the same as that of paralle
connection control.
>Anti-nuisanceWhen the lift travels to the furthest floor, it will remove all the internal selective register. If it has load testes
it will have three light-load internal selections at most.
>Emergency automatic
leveling travel
After the electric net power failure, the lift emergency automatic-leveling control device supplies power
to travel leveling so that the passengers can leave there safely.
>Hoist-way hall arrival gongUnder the condition of normal travel arrival, voice announcer is used to announce the related
passengers’ Information.
>Hoist-way hall arrival gongThe electric gong that is installed In the car announces the passenger lift arrival to vast passengers.
>Intellectual calling serviceThe electronic gong in the waiting zone announces the lift arrival to the waiting passengers.
>Intellectual calling serviceThe car command or hoist-way hall calling can be locked or connected through the special Intellectual Input equipment
>Service to the handicappedMan-machine interface specially serves the handicapped people.
>Electronic Punch Card SystemThe users shall swipe card In using the elevators. Those who do not have cards or have no jurisdiction can’ t use the elevators. It enlarges the safety management of the house property personnel and effectively saves power loss In the buildings.
>Energy feedback deviceIt offers regenerated lift power to the buildings. It is effectively applicable for lighting In the buildings etc.
so as to reduce the consumed power.