Tower Elevator

Tower Elevator

The tower elevator is mainly used as the special elevator for the structure facilities at the independent height (100-500 meters) with special purpose. It is designed with the unique tractor equipped downwards and anti-swing and anti-strong interference signal processing system. Due to the extension of the steel rope, it is specially designed with the smooth creep compensation device in the door area that makes no difference in terms of the operating quality between this elevator and the regular.

Introduction

The difference with the general passenger elevator

SANEI tower elevator is mainly used in special purpose independent height (100-500 m) structure of the special elevator. The unique design of the traction machine and anti swing. Due to the tension of the wire rope, the door area is designed to compensate for the smooth movement of the device, so that the quality of the elevator and the elevator is no difference.

Integrated control system, open up a new green process

SANEI integrated control system is a new generation of intelligent vector control system integration, integrated dual 32 bit computer system, CAN serial communication, the closed-loop vector control technology, sensor technology, load load compensation starting model PWM dead time compensation technology, the elevator control and drive combined with Canbus, Modus communication will be perfect really, to achieve the integration of the whole device has compact structure, small size, less wiring, higher reliability, more simple operation, more economical.

Permanent magnet synchronous gearless traction machine, set off a new green revolution

Compared with the traditional technology, the permanent magnet synchronous gearless traction machine can save 40% of energy, and does not need to replace oil, oil pollution and low noise.

Matching energy regenerative feedback technology, playing a new green movement

The high purity renewable energy generated, unloading the burden of the grid, to maintain the elevator room normal temperature, prolong the life of the elevator, reduce harmonic pollution, purify the grid environment, the elevator energy consumption reduced by 30%~70%. Improve operating comfort, achieve perfect control.

Parameter Table

Rated loadPersonsDrag methSpeedNet dimension of carDimension of door openingDimension of hoistwayDimension of machine roomOver headPit depth
WidthDepthWidthHeightWidthDepthWidthDepthHeight
kg 

V

V

V

F

m/sABEFCDRTHQP
45061.0140085080021001900150026003300250043001400
63081.0/1.5/1.75140011008002100190017002600350028004300/4500/46001400/1600/1600
800101.0/1.5/1.75/2.0140013508002100190020002600380028004300/4500   4600/49001400/1600  1600/2100
1000131.0/1.6/1.75/2.0160015009002100220021503000420028004300/4500   4600/49001400/1600  1600/2100
1250161.0/1.6/1.75/2.01950140011002100260021003200420028004500/4600  4600/49001500/1600  1700/2200
1600211.0/1.6/1.75/2.01950175011002100260026003500450028004500/4600  4600/49001500/1700  1700/2200

Details PC version

Standard Function

Standard FunctionFunction Description
>Brake detection and protectionOpen and closed through real-time monitoring of the brake brake arm detection switch. When the brake is not required when opened. The system will not allow the elevator.
>The correction speed and the number of floors of stationThe system in operation is detected in the end station after the switch. The elevator will force the speed and automatic correction of floor display.
>Limit protectorThe system detects the limit switch action, will immediately stop the elevator running.
>Maximum protectionThe system detects the limit switch action, the whole system will immediately power down.
>Overspeed protectionWhen the elevator up and down more than 1.2 times the rated speed, cut off the control power supply, the elevator will stop running.
>Layer station floor, direction displayThe station shows the elevator floor and the direction to be run.