Dust free (clean) Elevator

Dust free (clean) Elevator

Sanei dust free (clean )elevator is designed referring to GB50073 dust free environment, which is mainly applied into the labs of photo-electricity and pharmaceuticals, the labs with clean requirements, clean, dust free and sterilized workshops, sophisticated instrument works and the industries including the biology, micro-particle and nano etc, and the environment places requiring the cleanliness level of class100, class1000,class10000, class100000.

Introduction

Wide open door, free access

In order to facilitate the free access of large volume of goods, SANEI large tonnage cargo elevator products are multi fold car structure, so that when the door opens to reach a larger width.

High strength material, anti-aging

SANEI large tonnage truck lift not only the use of high-strength materials to make cars, but also to strengthen the design of the car site, making their products more durable, not easy to aging.

No difference, no more miles than

SANEI large tonnage cargo elevator with a small advantage to lay the foundation of the brand, the accuracy of its products can be controlled within the millimeter range.

Parameter Table

Rated loadDrag methodRated speedNet dimension of carDimension of door openingDimension of hoistwayDimension of machine roomOver headPit depth
WidthDepthWidthHeightWidthDepthWidthDepthHeight
kgm/sABEFCDRTHQP
Rated loadDrag methodRated speedNet dimension of carDimension of door openingDimension of hoistwayDimension of machine roomOver headPit depth
WidthDepthWidthHeightWidthDepthWidthDepthHeight
kg 

V

V

V

F

m/sABEFCDRTHQP
10000.5/1.015001800130021002400210035003500260043001400
16000.520002000150022002800235035004000260044001400
20000.520002400160022002950275035004500260045001400
30000.525002600200022003600295043004700280045001400
50000.25/0.530003300260024004450365055005500280048001500/1600

Details PC version

Standard Function

Standard FunctionFunction Description
>Brake detection and protectionOpen and closed through real-time monitoring of the brake brake arm detection switch. When the brake is not required when opened. The system will not allow the elevator.
>The correction speed and the number of floors of stationThe system in operation is detected in the end station after the switch. The elevator will force the speed and automatic correction of floor display.
>Limit protectorThe system detects the limit switch action, will immediately stop the elevator running.
>Maximum protectionThe system detects the limit switch action, the whole system will immediately power down.
>Overspeed protectionWhen the elevator up and down more than 1.2 times the rated speed, cut off the control power supply, the elevator will stop running.
>Layer station floor, direction displayThe station shows the elevator floor and the direction to be run.