(Small Machine Room) Passenger Elevator

Vertical Traffic

SANEI (small machine room) passenger elevator integrates advanced security, energy saving and mute etc, and upgrades its configuration to a brand-new level, and creates the sample of vertical traffic for all the buildings, and satisfy the needs in the places including the hotels, office buildings and shopping malls etc.

Introduction

There is standard five-party communication configuration, in case of the emergency during application and maintenance.
Many kinds of mute technologies are applied, which can reduce the noise pollution to the environment significantly while providing quiet riding experiences for the passengers.
Lighting with LED green light source can convert over 90% electric energy into optical energy, which can save energy by over 80% comparing with the traditional lighting.
The energy feedback device is chosen to convert the potential energy generated by the elevator into the electric energy feedback grid, and reduce the energy consumption significantly and guarantee its green operation.
The smart control mode is chosen to reduce the operating time of the elevator and improve its transportation capacity, and pick up and send off the designated passengers in fixed time,

Parameter Table

Rated Load
(kg)
personsDrag methodRated
Speed(m/s)
Net dimension of car(mm)Dimension of door opening
(mm)
Dimension of hoistway(mm)Dimension of machine room(mm)Over Head(mm)Pit depth(mm)
WidthDepthWidthHeightWidthDepthWidthDepthHeight
ABEFCDRTHQP
4506 

 

V

V

V

F

1.01100110080021001900150019001500250044001400
63081.0/1.6/1.75140011008002100190017501900175025004400/4500/46001400/1600/1600
800101.0/1.6/1.75140013508002100195021001950210025004400/4500/46001400/1600/1600
1000131.0/1.6/1.75/2.0160015009002100210021502100215025004400/4500/4600/49001400/1600/1600/2100
1150151.0/1.6/1.75/2.0185014009002100240021002400210025004400/4500/4600/49001400/1600/1600/2100
1250161.0/1.6/1.75/2.0195014009002100250021002500210025004400/4500/4600/49001400/1600/1600/2100
1350181.0/1.6/1.75/2.01950150011002100260022502600225025004400/4500/4600/49001400/1600/1600/2100
1600211.0/1.6/1.75/2.01950175011002100255024502550245025004400/4500/4600/49001400/1600/1600/2100

Details PC version

Well layout

Standard Function

FunctionDescription of functions
>Automatic operationThe lift automatically runs and stops, opens / shuts the door according to designated command.
>Operation by operatorThe lift automatically runs and stops, manually shuts the door according to designated command.
>Overhaul operationUnder repair and inspection conditions, the lift runs at inspection speed through operating
“slow up / slow down” buttons.
>Automatic door-shut
time-delay
After the car door has been opened completely, it keeps the door open condition. It automatically
shuts the dnnr after time-delav.
>Call for opening of this floorWhen the lift is shutting the door or it does not start but has closed the door, when there is any
outer calling from this landing, it will reopen the door.
>Light curtain protectionWhen optical curtain has been shaded,it immediately
stops door-shut action and automatically opens the door.
>Overload none door-shutIt does not shut the door in overload. And it is bright from overload lamp. The buzzer rings.
It shows CZ or overload In the car and does not start the Ilft
>Full-load direct runningWhen it reaches the rated load, it only responds to internal selection instead of outer calling.
>Automatic lighting controlIn the stipulated time, If the lift does not receive any travel command, the lighting will a utomatically
die out. It automatically opens at command.
>Firefight returnWhen It starts home landing fire-fighting switch, all the commands will be cancelled then.
The lift Immediately drives to the designated landing and park there.
>Mal-operation removalRepeatedly operate internal selective button to cancel mal-operation registration
>Main contactor protectionAfter the lift executes door-shut command, if the door has not been closed within the
stipulated time, it will re-open the door and then shut it again.
>Service floor settingThe lift only serves the set floor.
>Home landing floor settingUnder the automatic condition, if there is automatic ally run to the set landing. no command within certain period, the car will
>Landing floor, direction display in the carIt shows the landing floor of the lift, the direction where the lift is going to travel in the car,
>Direction chosen by driverThe running direction Is determined by the driver’s directive.
>Trouble diagnosisWhen there Is something wrong in the travel process, it will automatically diagnose the trouble
cause, display in the operation panel and automatically store the latest trouble Information.
>Safety circuit protectionIf safety circuit is disconnected, the lift will immediately stop the travel.
>Door Interlocking
protection
If It closes all of door Interlocking, it can then start the Ilft. If door Interlocking is disconn ected or
trembled, the lift will stop the operation.
>Travel contactor
protection
The system can detect whether motor circuit contactor action is reliable or not. If any abnorma
condition happens, it will stop the lift travel.

 

FunctionDescription of functions
>Brake test protectionIt Implement real-time monitor to the brake open / shut through brake arm test switch. If the brake
has been opened improperly, the system will not allow the lift to start.
>Terminal speed change and landing floor number correctionAfter the system detect terminal switch in travel, the lift will be forced to change the speed and
automatically correct the landing floor display.
>Position-Limit protectionIf the system detects limit switch action, It will immediately stop the lift travel.
>Limit protectiorIf the system detects limit switch action, the whole system will Immediately lose power
>Over-speed protectionWhen the lift up / down exceeds 1.2 times of the rated speed, it will cut off control mains and stop the lift travel.
>Landing floor, direction displayThe floor landing shows the landing floor that the lift travels and where it travels also.

Optional Function

FunctionDescription of functions
>Opposite door service settingCorrectly open / shut the door in the corresponding floor according to service setting.
>Fire-fighting runningAfter fire switch is closed, the system enters into fire-fighting running.
>Parallel connection controlTwo-lift parallel connection control automatically responds the command according to rapid energy-saving
principle so as to Increase the lift travel efficiency.
>Group supervisionThe system can simultaneously control the travel of eight-lift. The function is the same as that of paralle
connection control.
>Anti-nuisanceWhen the lift travels to the furthest floor, it will remove all the internal selective register. If it has load testes
it will have three light-load internal selections at most.
>Emergency automatic
leveling travel
After the electric net power failure, the lift emergency automatic-leveling control device supplies power
to travel leveling so that the passengers can leave there safely.
>Hoist-way hall arrival gongUnder the condition of normal travel arrival, voice announcer is used to announce the related
passengers’ Information.
>Hoist-way hall arrival gongThe electric gong that is installed In the car announces the passenger lift arrival to vast passengers.
>Intellectual calling serviceThe electronic gong in the waiting zone announces the lift arrival to the waiting passengers.
>Intellectual calling serviceThe car command or hoist-way hall calling can be locked or connected through the special Intellectual Input equipment
>Service to the handicappedMan-machine interface specially serves the handicapped people.
>Electronic Punch Card SystemThe users shall swipe card In using the elevators. Those who do not have cards or have no jurisdiction can’ t use the elevators. It enlarges the safety management of the house property personnel and effectively saves power loss In the buildings.
>Energy feedback deviceIt offers regenerated lift power to the buildings. It is effectively applicable for lighting In the buildings etc.
so as to reduce the consumed power.